<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\CommandsStyleSheet.xsl"?>
<Command>
<Name>plot series &lt; enable | disable &gt;</Name>
<Description>
<DescriptionText><text>
This command can be used to enable or disable series plot mode.
A series plot is one of a set of plots that are of fairly narrow
mainscan width, and positioned next to each other on the media.
Typically, one parameter is modified for each plot, so that the
whole series can be analysed to detect the effect that changing
the one parameter has on the output.
</text></DescriptionText>
<DescriptionText><text>
When series plotting is enabled, the carriage is not returned to the
original edge search start position after a plot, but instead is
moved to the next plot position as determined by the inter-plot gap.
This continues for each subsequent plot until series plotting is
disabled.
</text></DescriptionText>
</Description>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Gravure</TextApplies></ListItem>
<ListItem><TextApplies>Japanese_Newspaper_OEM_Engine</TextApplies></ListItem>
<ListItem><TextApplies>Lotem_400_Fiber_Head_Machine</TextApplies></ListItem>
<ListItem><TextApplies>Lotem_800_Fiber_Head_Machine</TextApplies></ListItem>
<ListItem><TextApplies>Lotem_Quantum</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_400</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_800</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Slave_MCE_Firmware</TextApplies></ListItem>
<ListItem><TextApplies>Thermoflex</TextApplies></ListItem>
<ListItem><TextApplies>Think_Motion_Controller</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_Series_4</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Notes>
<DescriptionText><text>
Series plots are disabled by default.  This command affects both test
plots and workstation plots.  Series plotting should be disabled when
performing workstation plots.
</text></DescriptionText>
</Notes>
<Availability>
<DescriptionText><text>
This command is available.
</text></DescriptionText>
</Availability>
<Access>
Expert
</Access>
<LastModified>
11-Jun-2001
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:25:17 2008 PST
</Updated>
<Links>
</Links>
</Command>